Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Warning

Please, contact Komet Sales 24 hours previously so they can generate the Scanner Username and Password. Also, make sure to send us the IP address to where the scanner will be connected to so we can create everything on our end.

Overview


Excerpt

This section explains the recommended hardware for the scanners as well as the SSH setup process.


Recommended Hardware

Any device with a barcode reader, internet access, and that support an SSH connection will serve. In order to efficiently scan fresh cut flower boxes, a pistol grip scanner would be the best option.  Regardless of the make and model heavy duty equipment should be used in order to survive the conditions in the warehouse.

 

Wi-Fi

The scanning application runs in real time and therefore, it needs to be connected to the internet in order to run. We strongly suggest that you perform a Wi-Fi site survey in your warehouse(s) with a company that has experience with wireless infrastructure.

 

WarningPlease, contact Komet Sales so they can generate the Scanner Username and Password. Also, make sure to send us the IP address to where the scanner will be connected to so we can create everything on our end

.


SSH Setup

Komet Sales uses a text based application that is executed via SSHconnection.  In order to SSH connection.  To connect to the scanning server, you will need a terminal program running on the scanner with SSH support (i.e.: TelnetCE, Wavelink or others).  Once you have the software on the scanner you will need to create a profile which will require the following information:

 

  • Host (the IP address of the scan server)
  • User
  • Password
  • Port


Info
titleConnection Information

This information will be provided during the implementation process. Keep in mind that a Komet Sales company user is required exclusively to set up and use the scanner functions.

Server Settings

  • Host: 174.129.20.191
  • Port: 22 (SSH)

 

Scanner Setup Settings

 


Warning
titleImportant

The next instructions apply for the Motorola Symbol CRD 9000-1000. They may vary considerably depending on the device model.

 


To setup the scanner, follow these instructions:

Ui steps
sizesmall


Ui step

Open the TelnetCE or WaveLink program (Start >> Programs) in the scanner.


Ui step

 Hit "Options" on the bottom left hand corner.


Ui step

 Go to Configure >> Host Profiles.


Ui step

 Use "SYSTEM" as password (case sensitive).


Ui step

 If the profile exists, select it and select "Edit".  If it does not exist select "Add".


Ui step

 Configure the profile.

  1. Alias: The name of the profile.  Example: Your Company Name.
  2. Emulation: Choose VT220 from the list.
  3. Address: The scan server IP address.
  4. Check the "Use SSH Encryption" checkbox (this requires the SSH extension is installed).
  5. Port: 22 (the SSH port).
  6. Click "Save".


Ui step

 The system will now open the "Configuration" options for the profile where you will be able to configure the following settings under each of these tabs (everything else stays with the defaults):

  1. SSH Autologin
    1. Name: the SSH username that's used to connect to the SSH server.
    2. Password: the SSH password.
  2. Display
    1. Uncheck the "Vertical Scrollbar" and "Horizontal Scrollbar".


Ui step

Hit the "OK" button on the upper right hand corner of the screen.


Ui step

Click on the Save button from the "Edit Host Profile" window.


Ui step

 Choose the new or updated profile from the "Edit Host Profile" window and click Done.

  • Emulation: VT220
 



Scanner Setup SSH Support

Ui steps
sizesmall



Ui step

Conect the scanner gun to a computer with Windows and install the Microsoft Software for Mobile Devices.



Ui step

Download the file  in the computer where the scanner gun is connected and edit the extesion from .txt to .exe. Execute the .exe file and follow the Wizard steps for the installation. 